วันพฤหัสบดีที่ 28 เมษายน พ.ศ. 2559

CWL Limit Switch - Akela

CWL Limit Switch - Akela




CWL Limit Switch          
   

   Features                                               
    -Double-circuit type of limit switch , is widely used
   -With strong aluminum cast outer shell
   -High mechanical strength
   -Structure preventing oil , water and pressure
   -Indicating plate with setting position is installed in il ,
    so it is easy to maintain
   -Various of actuators is taken convenience for using
   -Built-in contact stand has double-spring , so it has long
  Mechanical life 


 Contact Form                                    
         Open    (4)           (3)     Open
                    (1)          (2)     
        Close                       Close

 Characteristic                                    
Operation speed
1mm-2m/s
Operating frequency
Mechanical : 120 operation/minute Electical : 30 operations/minute
Contact resistance
15m  max. (intial value)
Insulation resistance
100m  min. (at 500 VDC)
Dielectric strength
1000 VAC,50/60 Hz for 1 minute between teminais of the same poiarity
1500VAC,50/60 Hz for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC,50/60 Hz for 1 minute between each terminal and ground
Vibration
  10-55Hz , 1.5mm double amplitude
Shock
Mechanical durable : 1,000m/Sec  (about 100 G’s)
Malfunction : 300m/Sec (about 30G’s)
Ambient temperature
= -10  *  +80 c
Humidity
<95% RH
Life
Mechanincal : 15,000,000 operations above (under rater OT)
Electrical : 500,000 operations above
Wright
About 275g
Degree of protection

IEC specification : IP 67







 Ratings                                    
Rated
voltage
Noninductive Load (A)
Inductive Load (A)
Resistance Load
Lamp Load
Inductive Load
Motor Load
NC
NO
NC
NO
NC
NO
NC
NO
125VAC
10
5
3
1
3
2
1.5
1
1.5
1
0.8
0.5
10
5
3
1.5
5
3
1.5
1
2.0
1.0
0.8
0.5
250VAC
480VAC
600VAC
8VDC
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
14VDC
30VDC
125VDC
250VDC




















 NOTES : 1. Inductive load has a power factor of 0.4 min. (AC) and a time constant of  7 msec. max. (DC)
                  2.Lamp loan has an inrush current of 10 times the steady-state current,
                    while motor load has an inrush current of 6 times the steady-state current.

 
 








 Operating Characteristics                              

Model
CWLCA
2-2
CWLD2
CWLNJ
CWJNJ
-S2
CWJCA
12-2-Q
CWLCL
OF  (Max.)
1360g
2720g
150g
29g
136g
142g
RF  (Min.)
227g
910g
-
-
227g
28g
PT  (Max.)
20
1.7mm
28mm
28mm
20
20
TP * 10%
30
5.6mm
-
-
30
30
MD  (Max.)
12
1mm
-
-
12
12
OT  (Min.)
2720g
-
-
-
2720g
200
TT   (Min.)
50
6.5 * 0.8mm
-
-
50
50
Model
CWLCA
32-41
CWLD
CWLNJ
-2
CWLNJ
-30
CWLD1
CWLD3
OF  (Max.)
1200g
2720g
120g
80g
2720g
2720g
RF  (Min.)
-
910g
-
-
910g
910g
PT  (Max.)
55
1.7mm
28mm
28mm
1.7mm
1.7mm
TP * 10%
35
6.4mm
-
-
5.6mm
5.6mm
MD  (Max.)
-
1mm
-
-
1mm
1mm
OT  (Min.)
-
-
-
-
2720g
2720g
TT   (Min.)
OP:90 *10
OP:34*2.8mm
-
-
6.5*0.8mm
9*0.8mm




  ติดต่อสอบถาม ราคาสินค้าได้ที่   faifathai.com